Advances in Clinical and Experimental Medicine

Title abbreviation: Adv Clin Exp Med
5-Year IF – 2.0, IF – 1.9, JCI (2024) – 0.43
Scopus CiteScore – 4.3
Q1 in SJR 2024, SJR score – 0.598, H-index: 49 (SJR)
ICV – 161.00; MNiSW – 70 pts
Initial editorial assessment and first decision within 24 h

ISSN 1899–5276 (print), ISSN 2451-2680 (online)
Periodicity – monthly

Download original text (EN)

Advances in Clinical and Experimental Medicine

2017, vol. 26, nr 4, July, p. 615–619

doi: 10.17219/acem/62692

PubMed ID: 28691409

Publication type: original article

Language: English

Download citation:

  • BIBTEX (JabRef, Mendeley)
  • RIS (Papers, Reference Manager, RefWorks, Zotero)

Comparison of titanium cable tension band and nickel-titanium patella concentrator for patella fractures

Quan-Ming Zhao1,A,B,D,F, Xiao-Feng Gu1,A, Li Cheng1,B, De-Hong Feng1,C

1 Department of Orthopedic Surgery, Wuxi People’s Hospital, Nanjing Medical University, Wuxi City, China

Abstract

Background. Patellar fractures account for approximately 1% of all fractures. Due to the patella’s importance as regards the extensor mechanism, effort should be made to preserve the patella. Several operative treatment methods have been introduced for patella fractures.
Objectives. This study aims to compare the clinical effect of a titanium cable tension band and nickeltitanium (NiTi) patella concentrator (NT-PC) in treating patella fractures.
Material and Methods. Thirty-nine patients with patella fractures were enrolled in this retrospective study. All the patients were treated via the open reduction internal fixation procedure using a titanium cable tension band or NT-PC. All the patients were followed up over an average period of 13 months. The main outcome measures were operation time, time of fracture union, postoperative complications, and Böstman knee scores. Statistical analyses were conducted between the 2 groups.
Results. All the patients were operated on successfully. The operation time of the NT-PC treatment group was less than that of the titanium cable tension band treatment group (p < 0.05). The mean scores at the final follow-up were 28.2 and 27.6 points in the titanium cable tension band and NT-PC groups, respectively. No significant difference was observed between the excellent and good results (p > 0.05).
Conclusion. Both titanium cable tension band and NT-PC showed good efficacy for the treatment of patellar fractures. NT-PC fixation, a new option for the treatment of patella fractures, is a simple and effective fixation method.

Key words

patellar fracture, clinical grading scale of Böstman, patella concentrator

References (19)

  1. Kakazu R, Archdeacon MT. Surgical management of patellar fractures. Orthop Clin North Am. 2016;47(1):77–83.
  2. Wild M, Windolf J, Flohé S. Fractures of the patella. Unfallchirurg. 2010;113:401–412.
  3. Böstman O, Kiviluoto O, Santavirta S, Nirhamo J, Wilppula E. Fractures of the patella treated by operation. Arch Orthop Trauma Surg. 1983;102:78–81.
  4. Radło W, Lorkowski J. Congenital dislocation of the patella in children and adolescents. Chir Narzadow Ruchu Ortop Pol. 1997;62(4):331–335.
  5. Witoński D, Keska R, Bira M. Reconstruction of the medial patellofemoral ligament with patellar tendon autograft – preliminary report. Chir Narzadow Ruchu Ortop Pol. 2010;75(1):42–46.
  6. Matsuo T, Watari T, Naito K, Mogami A, Kaneko K, Obayashi O. Percutaneous cerclage wiring for the surgical treatment of displaced patella fractures. Strategies Trauma Limb Reconstr. 2014;9(1):19–23.
  7. Della Rocca GJ. Displaced patella fractures. J Knee Surg. 2013;26: 293-299.
  8. LeBrun CT, Langford JR, Sagi HC. Functional outcomes after operatively treated patella fractures. J Orthop Trauma. 2012;26:422–426.
  9. Maniar RN, Nayak RM, Vatchha S, Singhi T. Periprosthetic patellar fracture fixation using suture anchors. Orthopedics. 2013;36(11):e1470–1473.
  10. Sayeed SA, Naziri Q, Patel YD, Boylan MR, Issa K, Mont MA. Patellar fractures following total knee arthroplasty: A review. J Long Term Eff Med Implants. 2013;23(4):331–336.
  11. Tang Y, Zhang YT, Fu QG, Zhang CC, Zhang X, Wang PF. Application of Ni-Ti patellar concentrator combined with Herbert screw and wirerope for the treatment of comminuted patellar inferior pole fractures. Zhongguo Gu Shang. 2013;26:457–459.
  12. Zhang Y, Wang P, Zhang C, Fu Q, Zhang X. Management of inferior polar comminuted fractures of patella and patellar tendon injury. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2011;25:976–979.
  13. Wada K, Liu Y. Thermomechanical training and the shape recovery characteristics of NiTi alloys. Mater Sci Eng A. 2008;481:166–169.
  14. Hao W, Zhou L, Sun Y, Shi P, Liu H, Wang X. Treatment of patella fracture by claw-like shape memory alloy. Arch Orthop Trauma Surg. 2015;135(7):943–951.
  15. Böstman O, Kiviluoto O, Nirhamo J. Comminuted displaced fractures of the patella. Injury. 1981;13:196–202.
  16. Yu XL, Xu C, Li SD, Zhan JD, Xu ZQ. Progress on treatment of transverse patella fractures with tension band fixation. Zhongguo Gu Shang. 2015;28(11):1069–1074.
  17. Rathi A, Swamy MK, Prasantha I, Consul A, Bansal A, Bahl V. Percutaneous tension band wiring for patellar fractures. J Orthop Surg. 2012;20:166–169.
  18. Dickens AJ, Salas C, Rise L, et al. Titanium mesh as a low-profile alternative for tension-band augmentation in patella fracture fixation: A biomechanical study. Injury. 2015;46(6):1001–1006.
  19. Saito M, Arakaki R, Yamada A, Tsunematsu T, Kudo Y, Ishimaru N. Molecular mechanisms of nickel allergy. Int J Mol Sci. 2016;17(2):202.